Table 40. Commodities thermal restrictions - Rear Accessed configuration(continued)
Chassis configuration
Ambient
temperature
ASHARE A2 (Max
35°C)
ASHARE A3 (Max
40°C)
ASHARE A4 (Max
45°C)
Edge1 (Max
50°C)
Edge2 (Max
55°C)
Optic cables / transceivers with 85°C spec support up to
45°C.
Transceiver above 2.5W is only supported with 85°C spec
up to 35°C.
PSU Dual PSU in redundant mode is required while ambient > 50°C, single PSU is not supported
Other Restrictions
Hot swap fan is not supported on XR5610
Min. cold boot temperature at 5°C. System operating temperature is -5°C55°C
DIMM Blank is required on empty slots.
OCP blank is required while empty slot.
PCIE blank is required on empty slots.
PSU blank is required on empty slot.
2.5-inch drive blank is required on empty slots.
Please notice that the fan speed may increase at ambient <0°C with SAS/SATA SSD. This indicates the fan is working as
design for overall system stability.