ASDA-B2 Chapter 7 Servo Parameters
Revision September 2013 7-25
Single Mode:
PT: Position control mode. The command is from external pulse or analog voltage
(external analog voltage will be available soon). Execution of the command
selection is via DI signal, PTAS.S: Speed control mode. The command is from
external signal or internal signal. Execution of the command selection is via DI
signals, SPD0 and SPD1.
T: Torque control mode. The command is from external signal or internal signal.
Execution of the command selection is via DI signals, TCM0 and TCM1.
Sz: Zero speed / internal speed command
Tz: Zero torque / internal torque commandMultiple Mode: Control of the mode selection
is via DI signals. For example, either PT or S control mode can be selected via DI
signals, S-P (see Table 7.A).
B: Torque output direction settings
Direction 0 1
Forward
Reverse
P1-02
PSTL Speed and Torque Limit
Address: 0104H
0105H
Operation
Interface:
Keypad/Software Communication
Related Section:
Section 6.6,
Table 7.A
Default: 0
Control
Mode:
ALL
Unit: -
Range: 00 ~ 11
Data Size: 16-bit
Display
Format:
Hexadecimal
Settings:
Disable or Enable speed limit function
0: Disable speed limit function
1: Enable speed limit function (It is available in torque mode)
Others: Reserved