Chapter 7 Servo Parameters ASDA-B2
7-42 Revision September 2013
P1-50
Reserved (Do Not Use)
Address: 0164H
0165H
P1-51
Reserved (Do Not Use)
Address: 0166H
0167H
P1-52 RES1 Regenerative Resistor Value
Address: 0168H
0169H
Operation
Interface:
Keypad/Software Communication
Related Section:
Section 6.6.3
Default: See the table below
Control
Mode:
ALL
Unit: Ohm
Range: 10 ~ 750
Data Size: 16-bit
Display
Format:
Decimal
Settings:
This parameter is used to set the resistance of the applicable regenerative resistor.
Model Default
For 750W models
100
For 1kW to 3kW models
40
P1-53 RES2 Regenerative Resistor Capacity
Address: 016AH
016BH
Operation
Interface:
Keypad/Software Communication
Related Section:
Section 6.6.3
Default: See the table below
Control
Mode:
ALL
Unit: Watt
Range: 30 ~ 3000
Data Size: 16-bit
Display
Format:
Decimal
Settings:
This parameter is used to set the capacity of the applicable regenerative resistor.
Model Default
For 750W models 60W
For 1kW to 3kW models 60W
VARITEL INGENIERIA ELECTRONICA S.A.
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics ASDA-B2 series and is the answer not in the manual?

Delta Electronics ASDA-B2 series Specifications

General IconGeneral
BrandDelta Electronics
ModelASDA-B2 series
CategoryServo Drives
LanguageEnglish

Related product manuals