Chapter 7 Servo Parameters ASDA-B2
7-68 Revision September 2013
P2-48
ANCL
Auto Resonance Suppression Detection Level
Address: 0260H
0261H
Operation
Interface:
Keypad/Software Communication
Related Section: N/A
Default: 100
Control
Mode:
ALL
Unit: N/A
Range: 1 ~ 300%
Data Size: 16-bit
Display
Format:
Decimal
Settings:
When the setting value is smaller, the system will become more sensitive to detect
and find the resonance.
When the value of
The setting value of P2-48 , the sensitivity of detecting resonance .
The setting value of P2-48 , the sensitivity of detecting resonance .
P2-49
SJIT
Speed Detection Filter and Jitter Suppression
Address: 0262H
0263H
Operation
Interface:
Keypad/Software Communication
Related Section:
Section 6.2.5
Default: 0
Control
Mode:
ALL
Unit: sec
Range: 0 ~ 1F
Data Size: 16-bit
Display
Format:
Decimal
Settings:
Setting Value of P2-49 Cutoff Frequency of Speed Loop Feedback (Hz)
00 2500
01 2250
02 2100
03 2000
04 1800
05 1600
06 1500
07 1400
08 1300
09 1200
0A 1100
0B 1000
0C 950
VARITEL INGENIERIA ELECTRONICA S.A.
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics ASDA-B2 series and is the answer not in the manual?

Delta Electronics ASDA-B2 series Specifications

General IconGeneral
BrandDelta Electronics
ModelASDA-B2 series
CategoryServo Drives
LanguageEnglish

Related product manuals