Chapter 7 Servo Parameters ASDA-B2
7-88 Revision September 2013
1. This adjustment function is enabled after parameter P2-08 is set to 20.
2. When executing any adjustment, the external wiring connected to analog speed or
torque must be removed and the servo system should be off (Servo off).
P4-11
SOF1 Analog Speed Input Drift Adjustment 1
Address: 0416H
0417H
Operation
Interface:
Keypad / Software Communication
Related Section: N/A
Default: Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Display
Format:
Decimal
Settings:
The adjustment functions from P4-11 through P4-19 are enabled after parameter
P2-08 is set to 22. Although these parameters allow the users to execute manual
adjustment, we still do not recommend the users to change the default setting value of
these parameters (P4-11 ~ P4-19) manually.
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4-12
SOF2 Analog Speed Input Drift Adjustment 2
Address: 0418H
0419H
Operation
Interface:
Keypad / Software Communication
Related Section: N/A
Default: Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Display
Format:
Decimal
Settings:
Refer to P4-11 for explanation.
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4-13
TOF1 Analog Torque Drift Adjustment 1
Address: 041AH
041BH
Operation
Interface:
Keypad / Software Communication
Related Section: N/A
Default: Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit