Interfaces Wide Area Networks (WANs)
Digi Connect EZ Mini User Guide
71
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}.
For example, to set Response timeout to ten minutes, enter 10m or 600s.
The default is 15 seconds.
12. Select the Test type.
Available test types:
n Ping test: Uses ICMP to determine connectivity.
If Ping test is selected, complete the following:
l Ping target: The type of target for the ping, one of:
o
Hostname or IP address of an external server.
o
Ping host: hostname or IP address of the server.
o
The Interface gateway. If Interface gateway is selected, an initial traceroute is
sent to the hostname or IP address configured in the SureLink advanced settings,
and then the first hop in that route is used for the ping test.
o
The Interface address.
o
The Interface DNS server.
l Ping payload size: The number of bytes to send as part of the ping payload.
n DNS test: Performs a DNS query to the named DNS server.
If DNS test is selected, complete the following:
l DNS server:The IP address of the DNS server.
n HTTP test: Uses HTTP(s) GET requests to determine connectivity to the configured web
server.
If HTTP test is selected, complete the following:
l Web server: The URLof the web server.
n Test DNS servers configured for this interface: Tests communication with DNS
servers that are either provided by DHCP, or statically configured for this interface.
n Test the interface status: Tests the current status of the interface. The test fails if the
interface is down. Failing this test infers that all other tests fail.
If Test the interface status is selected, complete the following:
l Down time: The amount of time that the interface is down before the test can be
considered to have failed.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take
the format number{w|d|h|m|s}.
For example, to set Down time to ten minutes, enter 10m or 600s.
l Initial connection time: The amount of time to wait for the interface to connect for
the first time before the test is considered to have failed.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take
the format number{w|d|h|m|s}.
For example, to set Initial connection time to ten minutes, enter 10m or 600s.
n Custom test: Tests the interface with custom commands.