Configuration and commands Special commands
XBee®-PRO 900HP/XSC RF Modules
204
The default flow control is NONE, so if you are using XCTU, CTS is not an issue. However, you can still
observe the behavior of the CTS line by monitoring the CTS indicator in the terminal or console.
Special commands
The following commands are special commands.
FR (Force Reset)
If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Resets the device through the UART. The device responds immediately with an OK and performs a
reset 100 ms later.
Parameter range
N/A
Default
N/A
PL (TX Power Level)
Sets or displays the power level at which the device transmits conducted power.
The device calibrates Power lever 4 and other levels are approximate.
Binary command
0x3C (60 decimal)
Parameter range
0 - 4
Parameter Configuration
0 +7.0 dBm, (5 mW)
1 +15.0 dBm, (32 mW)
2 +18.0 dBm, (63 mW)
3 +21.0 dBm, (125 mW)
4 +24.0 dBm, (250 mW)
Default
4
Bytes returned
1
Command mode options
The following commands are Command mode option commands.