AT commands I/O settings commands
XBee®-PRO 900HP/XSC RF Modules
96
Parameter range
0 - 5
0 - 1
Parameter Description
0 Disabled
1
SPI_CLK
2 ADC
3 Digital input
4 Digital output, low
5 Digital output, high
Default
0
D3 (DIO3/AD3)
Sets or displays the DIO3/AD3 configuration (pin 17).
Parameter range
0 - 5
Parameter Description
0 Disabled
1 SPI slave select
2 ADC
3 Digital input
4 Digital output, low
5 Digital output, high
Default
0
D4 (DIO4)
Sets or displays the DIO4 configuration (pin 11).
Parameter range
0, 1, 3 - 5