Configuration and commands Command mode options
XBee®-PRO 900HP/XSC RF Modules
207
CT (Command Mode Timeout)
Set or read the Command mode timeout parameter. If a device does not receive any valid commands
within this time period, it returns to Idle mode from Command mode.
Use the CN (Exit Command mode) command to exit Command mode manually.
Binary command
0x06 (6 decimal)
Parameter range
0x02 - 0xFFFFF [x 100 milliseconds]
Default
0xC8 (20 seconds)
Bytes returned
2
E0 (Echo Off)
Turns off the character echo in Command mode.
By default, echo is off.
Binary command
0x0A (10 decimal)
Parameter range
N/A
Default
N/A
Bytes returned
N/A
E1 (Echo On)
Enables character echo in Command mode. Each character that you type echoes back to the terminal
when E1 is active. E0 (Echo Off) is the default.
Binary command
0x0B (11 decimal)
Parameter range
N/A
Default
N/A