Configure the XBee-PRO 900HP RF Module Over-the-air firmware updates
XBee®-PRO 900HP/XSC RF Modules
32
file should be stored in order in the appropriate GPM memory blocks. The number of bytes that are
sent in an individual GPM WRITE frame is flexible and can be catered to the user application.
Example
The example firmware version has an .ebin file of 55,141 bytes in length. Based on network traffic, we
determine that sending a 128 byte packet every 30 seconds minimizes network disruption. For this
reason, you would divide and address the .ebin as follows:
GPM_BLOCK_NUM GPM_START_INDEX GPM_NUM_BYTES .ebin bytes
0 0 128 0 to 127
0 128 128 128 to 255
0 256 128 256 to 383
0 384 128 384 to 511
1 0 128 512 to 639
1 128 128 640 to 767
- - - -
- - - -
- - - -
107 0 54784 to 54911
107 128 54912 to 55039
107 256 101 55040 to 55140
Verify the new application
For an uploaded application to function correctly, every single byte from the .ebin file must be properly
transferred to the GPM. To guarantee that this is the case, GPM VERIFY functions exist to ensure that
all bytes are properly in place. The FIRMWARE_VERIFY function reports whether or not the uploaded
data is valid. The FIRMWARE_VERIFY_AND_INSTALL command reports if the uploaded data is invalid. If
the data is valid, it begins installing the application. No installation takes place on invalid data.
Install the application
When the entire .ebin file is uploaded to the GPM of the target node, you can issue a FIRMWARE_
VERIFY_AND_INSTALL command. Once the target receives the command it verifies the .ebin file
loaded in the GPM. If it is valid, then the device installs the new firmware. This installation process can
take up to eight seconds. During the installation the device is unresponsive to both serial and RF
communication. To complete the installation, the target module resets. AT parameter settings which
have not been written to flash using the WR command will be lost.
Important considerations
Write all parameters with the WR command before performing a firmware update. Packet routing
information is also lost after a reset. Route discoveries are necessary for DigiMesh unicasts involving
the updated node as a source, destination, or intermediate node.

Table of Contents

Other manuals for Digi XBee-PRO S3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee-PRO S3 and is the answer not in the manual?

Digi XBee-PRO S3 Specifications

General IconGeneral
BrandDigi
ModelXBee-PRO S3
CategoryControl Unit
LanguageEnglish

Related product manuals