AT commands MAC/PHY commands
XBee®-PRO 900HP/XSC RF Modules
79
ID (Network ID)
Set or read the user network identifier.
Devices must have the same network identifier to communicate with each other.
Devices can only communicate with other devices that have the same network identifier and channel
configured.
When receiving a packet, the device check this after the preamble ID. If you are using Original
equipment manufacturer (OEM) network IDs, 0xFFFF uses the factory value.
Parameter range
0 - 0x7FFF
Default
0x7FFF
MT(Broadcast Multi-Transmits)
Set or read the number of additional MAC-level broadcast transmissions. All broadcast packets are
transmitted MT+1 times to ensure they are received.
Parameter range
0 - 5
Default
3
PL (TX Power Level)
Sets or displays the power level at which the device transmits conducted power. Power levels are
approximate.
PL= 4 is calibrated and the remaining power levels are approximate.
Parameter range
Setting Power level
0 +7 dBm (5 mW)
1 +15 dBm (32 mW)
2 +18 dBm (63 mW)
3 +21 dBm (125 mW)
4 +24 dBm (250 mW)
Default
4

Table of Contents

Other manuals for Digi XBee-PRO S3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee-PRO S3 and is the answer not in the manual?

Digi XBee-PRO S3 Specifications

General IconGeneral
BrandDigi
ModelXBee-PRO S3
CategoryControl Unit
LanguageEnglish

Related product manuals