Legacy S3B hardware certifications Agency certifications - United States
XBee®-PRO 900HP/XSC RF Modules
259
FCC notices
IMPORTANT: The XBee-PRO XSC OEM RF Module has been certified by the FCC for use with other
products without any further certification (as per FCC section 2.1091). Modifications not expressly
approved by Digi could void the user's authority to operate the equipment.
IMPORTANT: OEMs must test final product to comply with unintentional radiators (FCC section 15.107
and 15.109) before declaring compliance of their final product to Part 15 of the FCC rules.
IMPORTANT: The RF module has been certified for remote and base radio applications. If the module
will be used for portable applications, please take note of the following instructions the device must
undergo SAR testing.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
n Re-orient or relocate the receiving antenna.
n Increase the separation between the equipment and receiver.
n Connect equipment and receiver to outlets on different circuits.
n Consult the dealer or an experienced radio/TV technician for help.
Limited modular approval
This is an RF module approved for Limited Modular use operating as a mobile transmitting device with
respect to section 2.1091 and is limited to OEM installation for Mobile and Fixed applications only.
During final installation, end-users are prohibited from access to any programming parameters.
Professional installation adjustment is required for setting module power and antenna gain to meet
EIRP compliance for high gain antenna(s).
Final antenna installation and operating configurations of this transmitter including antenna gain and
cable loss must not exceed the EIRP of the configuration used for calculating MPE. Grantee (Digi) must
coordinate with OEM integrators to ensure the end-users and installers of products operating with
the module are provided with operating instructions to satisfy RF exposure requirements.
The FCC grant is valid only when the device is sold to OEM integrators. Integrators are instructed to
ensure the end-user has no manual instructions to remove, adjust or install the device.
FCC-approved antennas
CAUTION! This device has been tested with Reverse Polarity SMA connectors with the
antennas listed in the tables of this section. When integrated into OEM products, fixed
antennas require installation preventing end-users from replacing them with non-approved
antennas. Antennas not listed in the tables must be tested to comply with FCC Section
15.203 (unique antenna connectors) and Section 15.247 (emissions).