Configuration and commands Networking and security commands
XBee®-PRO 900HP/XSC RF Modules
208
Bytes returned
N/A
PC (Power-up to Transparent operating mode)
Sets the device to power-up directly into Command mode from reset or power-on. If you enable the
PC Command with the SM Parameter set to 1, you can use the DI3 (pin 9) to enter Command mode.
If the PC command is enabled with the SM parameter set to 1, DI3 (pin 9) can be used to enter the
module into Command mode. When the device de-asserts (low) the DI3 pin, it wakes-up in Command
mode.
This behavior allows device DTR emulation.
Binary command
0x1E (30 decimal)
Parameter range
0 - 1
Parameter Configuration
0 Power-up to Idle mode
1 Power-up to Command mode
Default
0
Bytes returned
1
Networking and security commands
The following AT commands are networking and security commands.
AM (Auto-set MY)
Sets the MY (Source Address) parameter from the factory-set serial number of the device. The
address consists of bits 29, 28 and 13-0 of the serial number, in that order.
Sending AM displays the address.
Note This command is only supported on S3B modules.
Binary command
0x3A (58 decimal)
Parameter range
N/A
Default
N/A

Table of Contents

Other manuals for Digi XBee-PRO S3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee-PRO S3 and is the answer not in the manual?

Digi XBee-PRO S3 Specifications

General IconGeneral
BrandDigi
ModelXBee-PRO S3
CategoryControl Unit
LanguageEnglish

Related product manuals