Digitronic Digital Cam Switch Unit
Automationsanlagen GmbH CamCon DC50/51
After about 5 sec. the display returns to the configuration menu. This waiting time depends on the size
of the used EEPROM, since the memory has to be formatted. With the use of a 32k - EEPROM it is
increased to approximately 2 min. After this time the complete deletion is finished. All cams are erased,
all system registers have the standard value.
Now you can begin with the system setting.
To make your device operable, you have to set a minimum number of parameters on your CamCon.
This is the recommended order of the parameterization. You can find the neccessary information in the
corresponding chapters.
1) System setting, System upgrading See chapter "7.4.6. System upgrading" on page 63.
2) System setting, Cable length See chapter "7.4.4.1. The cable length" on page 59.
3) System setting, Measuring system See chapter "7.4.1. Measuring system" on page 45.
4) Unit configuration, hardware configuration,See chapter "7.5.6. Configure Hardware" on page 75.
If you have adjusted the inputs according to the corresponding chapters, the CamCon is ready and no
more error messages should occur. Of course we recommend to go through the whole system setting
menu to receive a maximum of user ability and comfort.
After the system setting you can begin with the cam programming.