Digitronic Digital Cam Switch Unit
Automationsanlagen GmbH CamCon DC50/51
7.5.3.4. Locking EEProm memory
If an PLC-controll writes or programs parameter, Cams or Delay-Times cyclical (eg. DC300 or CP16)
the unit's EEProm-Memory will be destroyed after a short time. If cyclical programming is, for a certain
reason, necessary, you therefore have to lock the EEProm.
Therefore select S-EE in menu "unit configuration" and change it by pressing to "locked". If the
EEProm is locked, all data will only be written to RAM and will be deleted if the voltage is switched off.
Attention: After having finished a complete deleting, this value is set to "unlocked" again.
,Version from: Aug. 04 Page: 73
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:hvssystem@hvssystem.com
Site web : www.hvssystem.com