11. Measuring the pressure
- connect the pressure gauge to the measuring point (inlet MP)
- max. pressure of oil at the operating temperature (40-60 °C) is 20-21,5 MPa (205-215
bar)
- the turning pressure is 5.5-7,0 MPa (55-70 bar)
- if you have to readjust the pressure, secure the new setting with a seal