Click New to create a new SIP profile, or click to edit the information of an existing SIP profile.
Parameter
Explanation
Name
The name of the SIP profile
Local Listening Port
The local listening port of SIP. If the SIP profile is used by a SIP trunk, the
port filled in here is the listening port for the SIP trunk.
NAT
Methods for NAT traversal, including static NAT (IP Address and Host),
dynamic NAT (uPNP/NAT-PMP), and STUN. NAT can also be disabled (off).
DTMF Type
There are three modes, including SIP Info, INBAND, RFC2833.
RFC2833-PT
RFC2833 payload coding. The default value is 101.
PRACK
Provisional Response ACKnowledgement
Session Timeout
The validity period of current registration. It is 1800 seconds by default.
Inbound Codec
Negotiation Priority
To take the remote device or the local device as priority for inbound codec
negotiation.
Assume local device supports PCMA, PCMU, G.729 and G.723, while the