12 Instructions for use | Oxylog VE300 SW 1.n
Safety-related information
2.8.7 Alarms
Failure to notice alarm signals may put the patient at risk.
Before operation, check that the visual and acoustic alarm signals are working
correctly. To do so, generate any alarm, e.g. O
2 supply pressure low.
Set the alarm volume so that alarm signals can be heard.
The user must stay within hearing range of the acoustic alarm signal.
Pay additional attention in environments where the surrounding noise interferes
with hearing the maximum alarm volume of the device (e.g., in a helicopter).
Make sure that the alarm system has not been rendered useless by setting the
alarm limits to extreme values.
Check the display regularly for optical alarm signals when the acoustic alarm
signals are silenced.
2.8.8 Accessories
The use of incompatible accessories may adversely affect the functional integrity of
the product. Personal injury and property damage may result.
Use only compatible accessories. The accessories that are compatible with this
product are listed in the list of accessories supplied with the product.
Do not use any antistatic or electrically conductive breathing circuits.
2.8.9 Connected devices
Any connected devices or device combinations not complying with the
requirements mentioned in these instructions for use may compromise the correct
functioning of the medical device and lead to an electric shock.
Before operating the medical device, strictly comply with the instructions for use
of all connected devices or device combinations.
Electrical connections to equipment not listed in these instructions for use or
these assembly instructions must only be made when approved by each
respective manufacturer.
2.8.10 Service
If service is not performed regularly, malfunctions may occur, which can result in
personal injury and property damage.
Perform service work as described in "Service".
2.8.11 Electromagnetic compatibility (EMC)
Medical electrical equipment is subject to special precautionary measures
concerning electromagnetic compatibility. During installation and before initial
operation, follow the information in section: "EMC Declaration" (page 121).
This device can be affected by other electrical devices.

Table of Contents

Other manuals for Dräger Oxylog VE300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Oxylog VE300 and is the answer not in the manual?

Dräger Oxylog VE300 Specifications

General IconGeneral
BrandDräger
ModelOxylog VE300
CategoryMedical Equipment
LanguageEnglish

Related product manuals