Setup
86 Operating Instructions 171/173 - 02.0 - 09/2019
7.12.2 Creating the equipotential bonding
The earthing cable conducts away any static charging to ground.
Fig. 51: Creating the equipotential bonding 
To create the equipotential bonding:
1. Secure the earthing cable (2) to the connection point on the 
control (3).
2. Guide the earthing cable (2) upwards to the machine.
3. Secure the earthing cable (2) with screw and tab connector 
to the connection point on the machine base plate (1).
(1) - Connection point of the machine 
base plate
(2) - Earthing cable
(3) - Connection point on the control