Programming the seam pattern
The actual pocket form is programmed under this menu item. The
programmed pocket is shown with the corresponding information in the
left half of the display.
The corresponding parameter symbols appear in the right half.
Select the required parameter with cursor keys ï”, ð”, ñ”or
ò”.
The symbol of the parameter selected appears in reverse video.
Press the OK key.
The corresponding submenu is called.
Seam-start flap shape
This parameter is used to select the shape of the flap at the seam start.
Three variants are available:
Straight flap
Slantingflap(left)
Slanting flap (right)
Select the required flap shape with cursor keys ï”or ð”.
Press the OK”key.
The flap-angle entry window appears.
Flap angle
Entry: 01 13 [mm]
4
15