Setting the basic functions
55
© 2010 Dürkopp Adler AG
POS. -2? is displayed on the OP1000. Move the pedal to the Pos -2 position and confirm with OK.
POS. -1? is displayed on the OP1000. Put the pedal in the Pos -1 position and confirm with OK.
POS. 0? is displayed on the OP1000. Put the pedal in the Pos 0 position and confirm with OK.
POS. Max? is displayed on the OP1000. Move the pedal as far forward as it will go and confirm with OK.
You go to the parameter menu after you have entered the last stage.
Parameter t 08 22 is used to display the various speed curves. A selection can be made from five (0 - 4) curves
that affect the acceleration of the upper part by their behaviour.
The different curves each relate to the maximum speed set under parameter t 08 00, the minimum speed set
under parameter t 08 01 and pedal stages set with parameter t 08 20.
12.11 Positions
L
C
P
Min
Max
Unit
Description
t
08
10
-
-
-
Setting the reference position
t
08
11
-
-
-
Setting the needle positions
t
08
12
0
359
°
Lower needle position (Position 1)
t
08
13
0
359
°
Thread lever up position (Position 2)
t
08
14
0
359
°
Direction finder position
t
08
15
0
359
°
on threading position