Technical information
23
© 2010 Dürkopp Adler AG
6 Technical information
6.1 Technical data
Rated values:
Voltage (U
N
) [V] 230, monophase
Frequency (f
N
) [Hz] 50/60
Current (control unit) [A] 1.6
Power (output) (P
2
) [W] 375
Speed (n
n
) [1/min] 4000
Torque (M
n
) [N
m
] 0.63
Motor moment of inertia (J
mot
) [kgcm²] 0.5
(without belt disc)
Operating mode S5 (40% ED at ts = 2.5 s)
Intermittent service with electrical braking,
relative power on time 40%, run time 2.5 s
Type of protection IP40
Insulation class L
Limits:
Rated voltage range [V] 190 - 240 + 20 %/- 10%
monophase
Speed (n
max
) [1/min] 6000
Torque (M
max
, short-term) [Nm] 3.5
Power (P2
max
, short-term) [W] 1500
Moment of inertia (J
mach
) [kg c] 4.5
of the machine, reduced
on the motor shaft
Operating conditions:
Ambient temperature [°C] + 5 - 45
Ambient temperature (average over 24h) [°C] < 35
Humidity (relative) 85% at 30 °C