E15h SPRAYER- Sprayer Setup Operation
3.17 ENABLE FULL ROW PER SECTION
Note: By default this function is selected OFF; therefore each section switch,
switches half a row ON and OFF.
When FULL ROW PER SECTION is enabled ON, then each section switch, switches
1 row ON and OFF. For example a 2 row sprayer which has only 1 solenoid
controlling each row, then ‘2’ sections would be selected in BOOM SECTIONS,
(see Section 3.13) and FULL ROW PER SECTION enabled ON.
• Press MENU
• Press ENTER to select SETUP
• Press ENTER to select SPRAYER SETUP
• Press DEC (down arrow) button, the screen advances to SPRAYER SETUP 2
• Press LINE 4 until focus is on FULL ROW PER SECTION
• Press ENTER.
An asterisk (*) will appear.
• Press INC/DEC buttons, to select ON or OFF.
• Press ENTER to accept changes.
3.18
ENABLE AUXILIARY FUNCTION
Note: The AUXILIARY function enables the operator to connect a set of lights OR
foam marker to the AUXILIARY plug on the sprayer wiring loom and switch the
lights OR foam marker ON or OFF from the console.
• Press MENU
• Press ENTER to select SETUP
• Press ENTER to select SPRAYER SETUP
• Press DEC (down arrow) button, the screen advances to SPRAYER SETUP 2
• Press LINE 4 until focus is on FULL ROW PER SECTION
• Press ENTER.
An asterisk (*) will appear.
• Press INC/DEC buttons, to select ON or OFF.
• Press ENTER to accept changes.
31
V 1.0 11/05