Chapter 10 INSTALLATION CHECKLIST
Single Machine System Installation Checklist

All packing materials and binding parts must be removed from the cabinet.

The UPS cabinet must be placed in a proper location for installation. Do not place the UPS under the air outlet of the
air conditioner.

All conduits and cables shall be laid properly to the UPS and any other auxiliary cabinets.

All power cables shall be in proper size and connected to the correct terminals.

The neutral wire has been installed as required.

The ground wire shall be properly installed.

The positive, negative and neutral wires of the battery shall be correctly installed.

The external alarm has been wired correctly. (Optional).

The external battery switch is turned off.

An alarm label has been attached to the external battery switch.

LAN drops have been installed. (Optional).

Connection to LAN has been completed. (Optional).

The REPO equipment has been fixed at an appropriate location, and the wires have been connected to the
corresponding terminals of the UPS correctly. (Optional).

If a normally closed REPO switch is used in the UPS, the 3rd and 4th pins of the REPO terminal block shall be
connected by jumpers.

All terminal cover plates have been installed.

Accessories are mounted in their installed locations and their wirings have already been connected within the UPS
cabinet. (Optional).

Fireproof mud shall be lled into gaps between the cables and the cabinetAdequate workspace exists around the UPS
and other cabinets.

The air-conditioning device has been installed and its operation is normal.

The surrounding area of the UPS’ installation site shall be clean and free of dust. (Eaton recommends that the UPS is
installed on a level oor suitable for computer or electronic equipment).

There is adequate workspace around the UPS and other cabinets.

Sufcient lighting is provided around all the UPS equipment.

A 220 VAC power supply socket is available within 7.5m (25ft) around the UPS.

The initial startup and operational inspection of the UPS or accessory case shall be performed by Eaton customer
service engineers.