41
CABINET AND COUNTERTOP PREPARA-
TION
of installation. In the absence of local codes, this ap-
pliance should be installed in accordance with the
-
ada, installation must conform to current Natural Gas
-
tain that the appliance being installed is correct for the
for gas supply requirements.
-
the range into nonstandard cabinets, minimum clear-
ances shown in the diagrams in this manual must be
maintained.
installed. For best performance, the range should be
placed away from drafts that may be caused by doors,
NOTES
• Ifcabinetstoragespaceistobeprovided
directly above the range, the risk of personal
injury may be reduced by installing a
ventilating hood that projects horizontally a
minimum of 5 inches beyond the face of the
cabinets.
• Therangemaybeinstalledushtotherear
wall. We recommend installing a
noncombustible material on the rear wall
above the range and up to the vent hood. It is
not necessary to install noncombustible
materials behind the range below the
countertop height.
• Theminimumdistancefromthesidesofthe
range above the countertop to combustible
side walls must be at least 10 inches.
• Allmodelsaredeliveredwitha3.5”
backguard from the factory. A 9”
backguard is available on the E36GF75GPS
AND E36GF76GPS as options.
• Utilitiesmaybelocated:Inthelowerleft
corner of the adjacent right cabinet. (Refer to
Figure 2)
IMPORTANT
• Contactyourlocalbuildingdepartmentto
verify compliance with local code
interpretation.