78
Removing the top burner igniter module:
1. Disconnect power from the range, and remove
the rear panel.
2. Disconnect the wires from the module, remove
the (3) screws holding the module to the rear of
the range and lift the module off.
Removing the convection fan relay:
1. Disconnect power from the range, and remove
the rear panel.
2. Disconnect the wires from the relay, remove
the (1) screw and loosen the other holding
the relay to the relay mounting bracket and slide
the relay out from under the loosened screw
and lift the relay out.
Removing the convection fan
relay mounting bracket:
1. Disconnect power from the range, and remove
the relay.
2. Remove the (2) screws holding the bracket to
the rear of the range and lift the bracket out.
Removing the broiler orice shield:
1. Disconnect power from the range, and remove
rear panel.
2. Remove the (4) screws holding the shield to the
back of the range.
Removing the broiler burner seal:
1. Disconnect power from the range and remove
broiler burner seal cover.