2. Carefullypullthesealovertheoriceassembly.
Removing the broiler orice assembly:
1. Disconnect power from the range, remove the
rear panel from the range and disconnect the
exgaslinefromtheoriceassembly.
2. While holding the locking nut with a pair
ofneedlenosepliers,turntheoriceassembly
counterclockwise.
Removing the oven vent:
1. Disconnect power from the range, remove the
backguard, and rear panel.
2. Remove the (2) screws holding the oven vent to
the top brace and lift vent out.
Removing the exible tubing between the
broiler valve in the broiler orice:
1. Disconnect power from the range, and remove
rear panel.
2. Using a 5/8 inch wrench disconnect the tubing
fromtheoriceassemblyandthebroilersafety
valve.
Removing the broiler safety valve:
1. Disconnect power from the range, and remove
rear panel.