faILUrE
Electrical components will not
operate.
Burner ames too large and
yellow.
Burner ame too small.
Flame goes out, when valve
is turned to the simmer posi-
tion.
Top burners, not burning
properly.
COrrECTION
1. Check fuse or circuit breaker.
2. Check for line to neutral
voltage, at the range terminal
block.
1. Check gas pressure at the oven
burner under ow. The
pressure reading should 5
inches of water column pressure
for natural. Is the pressure
reading correct?
1. Check gas pressure at the oven
burner under ow. The
pressure reading should 5
inches of water column pressure
for natural. Is the pressure
correct?
1. Has the simmer bypass jet been
turned?
1. Are the burner bases and heads
installed correctly?
2. Check gas pressure at the
oven burner under ow. The
pressure reading should be
5 inches of water column
pressure for natural. Is the
pressure correct?
If defective replace the fuse or reset the
circuit breaker. If good go to step (2)
If the voltage reading is correct, there’s
a wiring problem in the range, check the
range wiring.
If the voltage readings are incorrect, de-
fective house wiring or defective range
power cord.
Yes, check for something blocking the air
inlet to the burners.
No, check gas supply pressure, the pres-
sure regulator or for a restriction in the
gas line.
Yes, restricted orice.
No, defective regulator or low incoming
gas pressure.
Yes, readjusts the simmer bypass jet.
No, clean the bypass jet, and the simmer
burner orice.
Yes, go to step (2).
No, install burner bases in heads cor-
rectly.
Yes, checked the burner orices.
No, checked gas supply pressure, the
pressure regulator or for a restriction in
the gas line.
ChECK
Note: Always check the wiring between the components