Alarm Possible fault Action/machine status Reset Alarm Pag.
E91
Communication error between PCB
and display board
Wiring faulty; Control/display board faulty:
PCB faulty.
---------------- RESET 69
E92
Communication incongruence
between main PCB- display board
(versions not compatible)
Wrong control/display board;
Wrong PCB (do not correspond to the model).
Cycle interrupted. OFF/ON 69
E93
Incorrect configuration of appliance
PCB faulty; (Incorrect configuration data). Cycle interrupted. OFF/ON 69
E94
Incorrect configuration of washing
cycle
PCB faulty; (Incorrect configuration data). Cycle interrupted. OFF/ON 69
E95
Communication error between
microprocessor and EEPROM
PCB faulty. Cycle interrupted. RESET 69
E97
Incongruence between programme
selector and cycle configuration
Faulty PCB (Wrong configuration data). Cycle interrupted. RESET 69
EA1
Drum positioning (DSP) faulty
Motor belt broken; Wiring faulty; PCB faulty; DSP sensor faulty. Positioning phase skipped.
ON/OFF
RESET
70
EA6
DSP door opening faulty
Motor belt broken; Wiring faulty; Drum cover open. Motor faulty; PCB
faulty.
Cycle paused.
ON/OFF
RESET
71
EH1
Frequency power of appliance out of
limits
Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions. OFF/ON 72
EH2
Voltage too high
Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions. OFF/ON 72
EH3
Voltage too low
Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions. OFF/ON 72
EF1
Drain filter blocked
(drain phase too long)
Drain tube blocked/kinked/too high;
Drain filter dirty/blocked.
Warning displayed at the end of cycle
(specific LED).
START/RESET 73
EF2
Excessive detergent dosing
(excessive foam during draining)
Excessive detergent dosing; drain tube kinked/blocked;
Drain filter dirty/blocked.
Warning displayed after 5 attempts or
by the specific LED.
RESET 73
EF3
Aqua control intervention
Water leaks onto base frame; water control system defective. Water drain. ON/OFF RESET 73
EF4
Water fill pressure low, no signal of
flowmeter and solenoid valve open
Tap closed; water fill pressure low. ---------------- RESET 73
EF5
Unbalanced load
Final spin phases skipped. ---------------- RESET 73
EF6
Reset
----------------
No action to be performed, if continues
replace the PCB.
---------------- 73
EC1
Solenoid valve blocked with
flowmeter working
Wiring faulty; Solenoid valve faulty/blocked, PCB faulty.
Cycle blocked with door closed.
Drain pump always works (5 min., then
it stops for 5 min. ecc.).
RESET 74
Ed1
Data communication error between
WD board and PCB
Wiring faulty between PCB and WD board; WD board faulty; PCB
faulty.
Cycle interrupted. OFF/ON 75
Ed2
Drying heating element relay 1 faulty
Wiring faulty between WD board and thermostats; thermostats faulty;
WD board faulty, PCB faulty.
Cycle blocked with door open. RESET 76
Ed3
Drying heating element relay 2 faulty
Wiring faulty between WD board and thermostats; thermostats faulty;
WD board faulty, PCB faulty.
Cycle blocked with door open. RESET 79