How to use
53
Extra tittle. Add extra tittle information into text report about used Application and some of
configuration settings.
Footer. Specify a text-file to add its content to the end of text report.
Header. Specify a text file to add its content at the beginning of text report.
Logo. Specify an image-file to add as a logo picture into pdf-reports. If this value is blank,
then default (Eltra) logo is used.
Weighing
Settings applicable during weighing Phase.
Balance button. If set, balance button will be displayed, when waiting for a sample. In this
case Application minimum and maximum weights are ignored.
Furnace. Define a furnace state during weighing phase: open or close (FCM).
ID format. Specify format of generated ID.
Motor home. If this setting is set, then carousel will be rotated to position 1 before
opening the furnace.
Tare. If this setting is set, then FCM will demand a stable balance weight when adding
sample. Otherwise, unstable weight is accepted.
Pos: 9.4.12 /00 25 Überschriften /ELTRA 1.1 Übersc hriften/11 Cru cibles @ 7\ mod_1384254 260918_9.doc x @ 52270 @ 2 @ 1
7.6 Crucibles
Pos: 9.4.13 /00 10 ELTRA/0005 so ftware_help/Tga /How to use/Cr ucibles @ 7\ mod_138425 4225116_9.docx @ 52259 @ @ 1
Crucibles on the carousel are shown in the Crucibles window. When observing crucibles in the
Results window, it is possible to recognize crucible status and determine its type and condition
by the group. Browser window displays the worst status.
Crucible statuses:
Unknown crucible weight (not weighed yet)
Empty crucible
Crucible with the sample
Junked crucible
*)
Bad crucible
*)
Dump
*)
In the Browser window only
Junked crucible is an unstable crucible, when during analysis there was at least once a
moment, then balance can’t read a stable crucible weight.
If after certain time balance weight is unstable, then software will move carousel up/down in
order to align crucible vertically, if it is touching carousel. If weight is not stabilized, then there
will be an attempt of realigning carousel, by making a full carousel turn, in order to fix any
possible alignment issues. If weight is still unstable, then crucible is marked as a junk.
Junked crucible not necessary means that result of this crucible is bad. It is just an indicator to
the user.
Bad crucibles status means that either of two: result file was corrupted or edited manually.