EasyManua.ls Logo

Emerson 2000IW - Figure 5.18 Replacing the Pressure Regulator

Emerson 2000IW
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1019567 REV. 03 93
4. Disconnect the three air lines to the Pressure Regulator (Figure 5.17 Removing the Pressure
Regulator).
5. Loosen and remove the retaining ring nut. You can do this two ways:
Hold the retaining ring nut while turning the Pressure Regulator; or
hold the Pressure Regulator and loosen the retaining ring nut with pliers.
6. Remove the Pressure Regulator from the welder (
Figure 5.17 Removing the Pressure Regulator).
5.5.4.2 Replacing the Pressure Regulator
Figure 5.18 Replacing the Pressure Regulator
1. Place the Pressure Regulator into the welder as shown in
Figure 5.18 Replacing the Pressure
Regulator. Tilt the Pressure Regulator approximately 45 degrees with the arrow on the back of
the Pressure Regulator pointing up.
2. Hold the Pressure Regulator in place; then install and tighten the retaining ring nut.
CAUTION General Warning
Turn the new Pressure Regulator knob fully counterclockwise.

Table of Contents