102 1019567 REV. 03
Figure 5.24 Removing the Trigger Guard
5.5.9.1 Removing the Trigger Guard
1. Turn off the welder and unplug main power.
2. Turn air pressure to zero, then disconnect main air supply.
3. Open the left side cover. See
5.3 Opening and Removing the Left Side Cover (EDP 100-032-338).
4. Remove the Converter-Booster-Horn Stack (Section
5.5.8.1 Removing the Converter-Booster-
Horn Stack).
5. Lower the carriage and insert a T-handle wrench (or similar tool) as shown in
Figure 5.23
Removing the Converter-Booster-Horn Stack. If you need to lower the carriage further, adjust the
Mechanical Stop as shown in
Figure 5.25 Adjusting the Mechanical Stop.
WARNING General Warning
Turn air pressure to zero and disconnect the main air supply. Failure
to do this leave the welder under potentially dangerous air pressure.