1019567 REV. 03 83
5.4.6.3 Removing the Elevator Knob (EDP 200-064-015)
Figure 5.12 Removing the Elevator Knob
1. Turn off the welder and unplug main power.
2. Turn air pressure to zero, then disconnect main air supply.
3. Open the left side cover. See Section
5.3 Opening and Removing the Left Side Cover (EDP 100-
032-338)
4. Use a 1/8 in. Allen wrench to loosen the set screw until you can pull the Elevator Knob off the
shaft (
Figure 5.12 Removing the Elevator Knob).
5.4.6.4 Replacing the Elevator Knob
To replace the Elevator Knob, reverse the instructions above.
WARNING General Warning
Before servicing the welder, make sure to do the following:
1. Turn off the welder and unplug main power.
2. Turn air pressure to zero and disconnect your main air line connection.
Failure to do this leaves the welder under potentially dangerous air
pressure.
3. Wait approximately 2 minutes after unplugging the welder before touching
internal electrical components.
WARNING General Warning
Turn air pressure to zero and disconnect the main air supply. Failure
to do this leave the welder under potentially dangerous air pressure.