1019567 REV. 03 115
Figure 5.33 Removing the Linear Optical Encoder (IW+ Only)
5.5.16.1 Removing the Linear Optical Encoder
1. Turn off the welder and unplug main power.
2. Turn air pressure to zero, then disconnect main air supply.
3. Open the left side cover. See
5.3 Opening and Removing the Left Side Cover (EDP 100-032-338).
4. Carefully cut the tie wraps attaching the encoder cable to the Main Harness.
Read
Section
WARNING General Warning
Turn air pressure to zero and disconnect the main air supply. Failure
to do this leave the welder under potentially dangerous air pressure.
CAUTION General Warning
Note the number and location of the tie wraps.