1019567 REV. 03 77
3. Open the left side cover. See Section 5.3 Opening and Removing the Left Side Cover (EDP 100-
032-338).
4. Firmly grasp the Breaker On/Off switch and remove by pulling it straight toward you.
5. Check the current rating on the side of the Circuit Breaker, then check the Table below to be
certain the current rating matches your welder.
6. Remove the two nylon screws that secure the switchplate to the breaker.
7. Replace the faulty breaker and re-attach the switchplate.
8. Press new breaker back onto the male tabs taking care to line it up before inserting.
9. Close and secure left door.
10.Connect the main air supply.
11.Plug in main power.
12.Turn unit power On.
Table 5.1 Circuit Breaker Part Number
Breaker
Current Rating
Power Model Line Voltage Part Number
8A 1100W 2000IW/IW+ 200-240V 200-167-014R
17A 1100W 2000IW/IW+ 100-117V 200-167-015R
17A 2200W 2000IW/IW+ 200-240V 200-167-015R
20A 3300W 2000IW/IW+ 200-240V 200-167-027