22 1019567 REV. 03
Figure 2.3 Front Panel Displays, IW
Table 2.2 Front Panel Displays, IW
Item Name Function
1 Power Bargraph
This 20 segment bargraph displays the power level
during the Test mode; or the power applied to the
workpiece during a weld cycle. While in READY state,
the graph displays the peak power of the last weld
cycle. These readings can be expanded by altering DIP
switch settings. When using the 2x scale, the
uppermost segment will blink. Refer to Section 4.11.1
’Setting DIP Switches’, of your Operating Manual for
further information about DIP settings.
2 Numeric Display
During a weld cycle, indicates the current weld state
code, if enabled, or the currently selected parameter’s
value. At the end of the weld cycle, it displays alarms.
3 Up/Down Switches
Once you have selected weld parameters to change,
these four switches increase or decrease your selected
parameters displayed in the NUMERIC DISPLAY. From
left to right, these switches a re referred to as the FAST
DOWN switch, the SLOW DOWN switch, the SLOW UP
switch, and the FAST UP switch. Pressing these switches
will have no effect until you have selected parameters to
change. These switches will be disabled when Display
Lock is active.
4 Power Indicator Indicates that power to the welder is ON.
5 Reset Switch
Resets any resettable or latchable alarm condition
(indicated by the switch LED blinking). Holding RESET
prevents a weld cycle form starting. Releasing RESET
returns the welder to the READY state, if there are no
non-resettable errors.

Table of Contents