86 1019567 REV. 03
Figure 5.14 Removing the Nose Assembly
6. Hold the nose assembly in place, then remove the nose-retaining screw (
Figure 5.14 Removing
the Nose Assembly).
7. Slide the nose assembly off the right side cover (
Figure 5.14 Removing the Nose Assembly).
5.5.1.1 Replacing the Nose Assembly
1. If you have removed the oil drip plate (Figure 5.13 Nose Assembly Components and
Connections), replace the plate with the dimples and tab facing up.
2. Plug P31 into the Controller Board (
Figure 5.13 Nose Assembly Components and Connections).
3. Slide the nose assembly onto the right side cover (
Figure 5.14 Removing the Nose Assembly).
4. Hold the nose assembly in place; insert and tighten the nose retaining screw (
Figure 5.14
Removing the Nose Assembly).
5. Plug all remaining electrical connections into the Control Module (
Figure 5.13 Nose Assembly
Components and Connections).
6. Connect the air lines to Pressure Regulator and Down Speed Control Valve (
Figure 5.13 Nose
Assembly Components and Connections).
7. Connect the main air supply.
8. Close the left side cover. See Section
5.3 Opening and Removing the Left Side Cover (EDP 100-
032-338).