Example No. 2 Table
Output Table
BYTE
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Valve Coil
No. 7
Valve Coil
No. 6
Valve Coil
No. 5
Valve Coil
No. 4
Valve Coil
No. 3
Valve Coil
No. 2
Valve Coil
No. 1
Valve Coil
No. 0
1
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Valve Coil
No. 11
Valve Coil
No. 10
Valve Coil
No. 9
Valve Coil
No. 8
2
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
3
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Allocated and
Reserved
Input Table
BYTE
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
(Optional
)
Comm.
Module
Diagnostic Bit
Comm.
Module
Diagnostic Bit
Comm.
Module
Diagnostic Bit
Comm.
Module
Diagnostic Bit
Comm.
Module
Diagnostic Bit
Comm.
Module
Diagnostic Bit
Comm.
Module
Diagnostic Bit
Comm.
Module
Diagnostic Bit
1
(Optional
)
Sub-bus
Diagnostic Bit
Sub-bus
Diagnostic Bit
Sub-bus
Diagnostic Bit
Sub-bus
Diagnostic Bit
Sub-bus
Diagnostic Bit
Sub-bus
Diagnostic Bit
Sub-bus
Diagnostic Bit
Sub-bus
Diagnostic Bit
2
(Optional
)
Coil No. 7
Status
Coil No. 6
Status
Coil No. 5
Status
Coil No. 4
Status
Coil No. 3
Status
Coil No. 2
Status
Coil No. 1
Status
Coil No. 0
Status
3
(Optional
)
Coil No. 15
Status
Coil No. 14
Status
Coil No. 13
Status
Coil No. 12
Status
Coil No. 11
Status
Coil No. 10
Status
Coil No. 9
Status
Coil No. 8
Status
4
(Optional
)
Coil No. 23
Status
Coil No. 22
Status
Coil No. 21
Status
Coil No. 20
Status
Coil No. 19
Status
Coil No. 18
Status
Coil No. 17
Status
Coil No. 16
Status
5
(Optional
)
Coil No. 31
Status
Coil No. 30
Status
Coil No. 29
Status
Coil No. 28
Status
Coil No. 27
Status
Coil No. 26
Status
Coil No. 25
Status
Coil No. 24
Status
NOTE!
The Comm. Module Diagnostic Bits, Sub-Bus Diagnostic Bits, Coil Status Bits and
Power Status Bits are optional. The factory default condition is Diagnostic bits are
enabled. These bits may be disabled to optimize the logical size of the manifold

Table of Contents