176 E300 Design Guide
Issue Number: 1
Table 7-35 UPS power control parameter
Figure 7-22 Emergency power supply backup control
Parameter Detail
Ups Control Enable (O05) Enable, disable for UPS control
UPS Maximum Power Set point
(O06)
Maximum UPS power in kW. This setting prevents the UPS from being overloaded during emergency evacuation
with UPS control enable = On (1).
UPS evacuation current full load
limit (O07)
Defines the percentage full load current allowed during emergency evacuation with UPS control enable = On (1)
to prevent overloading, and to extend the operating time of the UPS power supply.
UPS evacuation current no load
limit (O08)
Defines the percentage no load current allowed during emergency evacuation with UPS control enable = On (1)
to prevent overloading, and to extend the operating time of the UPS power supply.