Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
410 E300 Design Guide
Issue Number: 1
8.13 Menu N: Storage
Mode: Open-Loop, RFC-A, RFC-S
* Only a value of 3 or 4 in this parameter is saved.
Parameter Cloning (N01) can also be used to initiate data transfer to or from an NV media card as described below for each possible value of this
parameter.
1: Read
Provided a parameter file with file identification number 1 exists on the NV media card then setting Parameter Cloning (N01) = 1 and initiating a drive
reset will transfer the parameter data to the drive (i.e. the same action as writing 6001 to Pr mm00. When the action is complete Parameter Cloning
(N01) is automatically reset to zero.
2: Program
Setting Parameter Cloning (N01) and initiating a drive reset will transfer the parameter data from the drive to a parameter file with file identification
number 1. This is the same action as writing 4001 to Pr mm00 except that the file will be overwritten if it already exists. When the action is complete
Parameter Cloning (N01) is automatically reset to zero.
3: Auto
Setting Parameter Cloning (N01) = 3 and initiating a drive reset will transfer the parameter data from the drive to a parameter file with file identification
number 1. This is the same action as writing 4001 to Pr mm00 except that the file will be overwritten if it already exists. When the action is complete
Parameter Cloning (N01) remains at 3.
If the card is removed when Parameter Cloning (N01) = 3, then Parameter Cloning (N01) is set to 0, which forces the user to change Parameter
Cloning (N01) back to 3 if auto mode is still required. The user will need to set Parameter Cloning (N01) = 3 and initiate a drive reset to write the
complete parameter set to the new card.
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
N01 Parameter Cloning
None (0), Read (1), Program (2),
Auto (3), Boot (4)
None (0) RW Txt NC US
N02
Media Card File Previously
Loaded
0 to 999 0 RO Num NC PT
N03 Media Card File Number 0 to 999 0 RW Num
N04 Media Card File Type
None (0), Open-loop (1), RFC-A (2), RFC-S (3),
Regen (4), User Prog (5), Option App (6)
RO Txt ND NC PT
N05 Media Card File Version 0 to 9999
RO Num ND NC PT
N06 Media Card File Checksum -2147483648 to 2147483647
RO Num ND NC PT
N07 Media Card Create Special File 0 to 1 0 RW Num NC
N08 Media Card Type None (0), SMART Card (1), SD Card (2)
RO Txt ND NC PT
N09 Media Card Read-only Flag Off (0) or On (1)
RO Bit ND NC PT
N10
Media Card Warning
Suppression Flag
Off (0) or On (1)
RO Bit ND NC PT
N11
Media Card File Required
Version
0 to 9999
RW Num ND NC PT
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save
N01 Parameter Cloning
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 4
Default 0 Units
Type 8 Bit User Save Update Rate Background write
Display Format Standard Decimal Places 0
Coding RW, Txt, NC
Value* Text
0 None
1 Read
2 Program
3Auto
4Boot