Parameter
Range(Ú)Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
E01 Nominal Elevator Speed 0 to 1800 mm/s
0 to 10000 mm/s
1000 mm/s RW Num US
E02 Sheave Diameter 1 to 32767 mm 400 mm 480 mm RW Num US
E03 Roping 1:1 (1), 2:1 (2), 3:1 (3), 4:1 (4) 1:1 (1) RW Txt US
E04 Gearbox Ratio Numerator 1 to 32767 31 1 RW Num US
E05 Gear Ratio Denominator 1 to 32767 1 RW Num US
E07 Nominal Elevator Speed rpm 1.00 to 4000.00 rpm 1480.14 rpm
39.48
rpm
RW Num US
E08
Open-Loop: Motor maximum
frequency
±VM_POSITIVE_REF_CLAMP1
54.8 Hz
RO Num US
RFC-A: Motor maximum speed
1644.6
rpm
RO Num US
RFC-S: Motor maximum speed
43.8 rpm RO Num US
E09
Open-Loop: Over Speed
Threshold
0.0 to 550.0 Hz
0.0 Hz RW Num PT US
RFC-A: Over Speed Threshold
0 to 40000 0 RW Num US
RFC-S: Motor Over Speed
Threshold
0.0 to 550.0 0.0 RW Num US
E10
Load Cell Compensation
Enable
Off (0) or On (1) Off (0) RW Bit US
E11 Load Cell Compensation Input -32768 to 32767 0 RW Num US
E12
Load Cell Compensation Filter
Time Constant
0 to 32767 ms 100 ms RW Num US
E13 Load cell compensation torque ±VM_USER_CURRENT % 0.0 % RW Num US
E14
Inertia Compensation Mode
Select
None (0), Torque (2) None (0) RW Txt US
E15
Inertia Compensation Total
Inertia
0.00000 to 1000.00000 kgm² 0.00000 kgm² RW Num US
E16 Torque Per Amp
0.00 to 500.00 Nm/A
1.60
Nm/A
RO Num ND NC PT
E17 Inertia Compensation Torque
±1000.0 % RO Num ND NC PT
E18
Inertia compensation
acceleration
-1073741.824 to 1073741.823
mm/s² x100
RO Num ND NC PT
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save