Issue Number: 1
Creep to floor:
When V2 to V10 is selected and active, this indicates the distance from the selected speed to V1 Speed Reference (G01) using the Deceleration Rate
(G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
When V1 Speed Reference (G01) is selected and active, this indicates the distance from V1 Speed Reference (G01) to a stop using Creep Stop
Deceleration Rate (G17) and Creep Stop Jerk (G18).
Direct to floor:
This indicates the distance from the selected speed to a stop using the Deceleration Rate (G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
Creep to floor:
When V2 to V10 is de-selected or a stop is requested, Peak Curve Measured Distance (G43) shows the distance that's accumulated until V1 Speed
Reference (G01) is reached. This is based on sampling the motor encoder feedback.
Direct to floor:
When V1 to V10 is de-selected or a stop is requested, Peak Curve Measured Distance (G43) shows the distance that's accumulated until a complete
stop. This is based on sampling the motor encoder feedback.
Indicates when peak curve operation has been activated during acceleration. This value is reset to Off (0) once a new travel has started.
When set to Off (0) the start optimizer is disabled.
When set to On (1) the start optimizer is enabled.
This feature is helps to overcome starting stiction for elevators fitted with a motor output gearbox, or for systems fitted with guide rail pads rather than
rollers.
G42 Peak Curve Setpoint Distance
Mode Open loop, RFC-A, RFC-S
Minimum 0 Maximum 32767
Default Units mm
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC
G43 Peak Curve Measured Distance
Mode Open loop, RFC-A, RFC-S
Minimum 0 Maximum 32767
Default Units mm
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, Num, ND, NC
G44 Peak Curve Activated
Mode Open loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, Bit
G45 Start Optimizer Enable
Mode RFC-A, RFC-S
Minimum 0 Maximum
1
Default 0 Units
Type 1 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW