E300 Design Guide 315
Issue Number: 1
This parameter selects which floor sensor correction input is used when performing a floor sensor correction in Creep to floor mode, Control Input
Mode (H11) = Creep To Floor (0).
When set to Floor Sensor IP (0), the floor sensor correction is performed using freeze input 2 via T28 digital input 5. When set to Creep Spd IP (1), the
floor sensor correction is performed when the creep speed is deselected.
0: Rising 1st
Floor sensor correction input is triggered on a rising edge of Digital input 5 and the first suitable edge produced by the trigger source causes the floor
sensor correction to be actioned.
1: Falling 1st
Floor sensor correction input is triggered on a falling edge of Digital input 5 and the first suitable edge produced by the trigger source causes the floor
sensor correction to be actioned.
When set to On (1), fast stop is enabled where the fast stop deceleration rate, Fast Stop Deceleration Rate (G29), is used to bring the elevator car to
a stop. The jerk is fixed internally to reach constant acceleration / deceleration in 200 ms or Fast Stop Deceleration Rate (G29) * 5.
The fast stop may be actioned in one of 2 ways:
Speed control:
In this mode one of the user speeds, V1 Creep Speed Reference (G01) to V10 Speed Reference (G10), is set to 0 mm / s and is selected, and Fast
Stop Enable (H26) = On (1), a fast stop is activated.
The user must reset the selected inspection speed such that a new inspection travel may begin.
Direction control:
In this mode if dual direction inputs are selected, Control Input mode (H11) = Priority 2 Dir or Binary 2 Dir (4 or 5), and the direction signal is removed,
and Fast Stop Enable (H26) = On (1), a fast stop is activated.
H24 Floor Sensor Correction Source Select
Mode RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Txt, US
Value Text
0 Floor Sensor IP
1 Creep Spd IP
H25 Floor Sensor Correction Edge Detection
Mode RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, Txt, US
Value Text
0 Rising 1st
1 Falling 1st
H26 Fast Stop Enable
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW