The large option module can only be inserted into slot 3. Additional standard option modules can still be installed and used in slot 2 and slot 1.
Figure 3-7 Installation and removal of the KI-Elv Keypad RTC
To install, align the keypad and press gently in the direction shown until it clicks into position.
To remove, reverse the installation instructions.
Figure 3-8 Connection of the CI-Elv Remote Keypad
1. KI-485 Adaptor
2. RJ-485 lead
3. Remote keypad (CI-Elv Remote Keypad)
N
The keypad options can be installed / removed while the drive is powered up and running a motor, provided the drive is not operating in keypad mode.
Table 3-2 Communications option
NOTE
1
2
3
Part number Communications option
82400000016100 KI-485 Adaptor - A removable adaptor which provides 485 comms interface. This adaptor supports 115 k Baud
4500-0096 CT USB comms cable