Issue Number: 1
If Maximum Speed Error Threshold (H15) = 0 then Trip 62 (Speed err) is disabled.
Maximum Speed Error (J57) shows the maximum speed error for the current travel. It is reset when a new travel begins.
This indicates the number of travels started for the system. It includes all complete and aborted travels i.e. every time Elevator Software State (J03) is
>1 the travel count increments.
The Output Power (J59) is the power flowing via the a.c. terminals of the drive. The power is derived as the dot product of the output voltage and
current vectors, and so this is correct even if the motor parameters are incorrect and the motor model does not align the reference frame with the flux
axis of a motor in RFC-A mode. For Open-loop, RFC-A and RFC-S modes a positive value of power indicates power flowing from the drive to motor.
For Regen mode a positive value of power indicates power flowing from the supply to the regen drive.
The output frequency is not controlled directly, but the Output Frequency (J60) is a measurement of the frequency applied to the motor.
The Output Voltage (J61) is the rms line to line voltage at the AC terminals of the drive.
This indicates the maximum power sampled in the previous travel. The value is taken from Output Power (J59) and is filtered using a first order 50 ms
time constant filter. This value is reset at the beginning of a new travel.
J58 Travel Counter
Mode Open-Loop, RFC-A, RFC-S
Minimum -2147483648 Maximum 2147483647
Default Units
Type 32 Bit Power Down Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, ND, NC, PT
J59 Output Power
Mode Open-Loop, RFC-A, RFC-S
Minimum −VM_POWER Maximum VM_POWER
Default Units kW
Type 32 Bit Volatile Update Rate 4 ms write
Display Format Standard Decimal Places 3
Coding RO, FI, VM, ND, NC, PT
J60 Output Frequency
Mode Open-Loop, RFC-A, RFC-S
Minimum -2000.0 Maximum 2000.0
Default Units Hz
Type 32 Bit Volatile Update Rate 4 ms write
Display Format Standard Decimal Places 1
Coding RO, FI, ND, NC, PT
J61 Output Voltage
Mode Open-Loop, RFC-A, RFC-S
Minimum −VM_AC_VOLTAGE Maximum VM_AC_VOLTAGE
Default Units V
Type 16 Bit Volatile Update Rate 4 ms write
Display Format Standard Decimal Places
Coding RO, FI, VM, ND, NC, PT
J62 Last Travel Maximum Power
Mode Open-Loop, RFC-A, RFC-S
Minimum 0.000 Maximum 32.767
Default Units kW
Type 32 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 3
Coding RO,ND, NC, PT