Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
L01 Drive Status
Inhibit (0), Ready (1), Stop (2), Scan (3), Run (4),
Supply Loss (5), Deceleration (6), dc Injection (7),
Position (8), Trip (9), Active (10), Off (11), Hand (12),
Auto (13), Heat (14), Under Voltage (15), Phasing (16) 
RO Txt ND NC PT
L02 Drive Warning Off (0) or On (1)
RO Bit ND NC PT
L03 Travel Interrupt Code 0 to 13 
RO Num ND NC PT
L04 Global Warning Off (0) or On (1)
RO Bit ND NC PT
L05 Drive OK Off (0) or On (1)
RO Bit ND NC PT
L06 Drive Active Off (0) or On (1)
RO Bit ND NC PT
L07 Standstill Indication Off (0) or On (1)
RO Bit ND NC PT
L08 At Zero Speed Off (0) or On (1)
RO Bit ND NC PT
L13 Rated Load Reached Off (0) or On (1)
RO Bit ND NC PT
L14 Regenerating Off (0) or On (1)
RO Bit ND NC PT
L15 Current Limit Reached Off (0) or On (1)
RO Bit ND NC PT
L16 Braking IGBT Active Off (0) or On (1)
RO Bit ND NC PT
L17 Braking Resistor Alarm Off (0) or On (1)
RO Bit ND NC PT
L18 Supply Loss Off (0) or On (1)
RO Bit ND NC PT
L19 Under Voltage Off (0) or On (1)
RO Bit ND NC PT
L20 Phase Loss Off (0) or On (1)
RO Bit ND NC PT
L21 Motor Overload Alarm Off (0) or On (1)
RO Bit ND NC PT
L22
Drive Over Temperature 
Alarm
Off (0) or On (1)
RO Bit ND NC PT
L23
Motor Thermistor Over 
Temperature Indication
Off (0) or On (1)
RO Bit ND NC PT
L24 Active Alarm
None (0), Brake Resistor (1), Motor Overload (2),
Ind Overload (3), Drive Overload (4), Auto Tune (5),
Limit Switch (6), Fire Mode (7), Low Load (8),
Option Slot 1 (9), Option Slot 2 (10), Option Slot 3 (11), 
Option Slot 4 (12) 
RO Txt ND NC PT
L25 Autotune Active Off (0) or On (1)
RO Bit ND NC PT
L26 Stop Motor Off (0) or On (1)
RO Bit ND NC PT
L27
Reverse Direction 
Commanded
Off (0) or On (1)
RO Bit ND NC PT
L28 Reverse Direction Running Off (0) or On (1)
RO Bit ND NC PT
L29 Trip 0 0 to 255 
RO Txt ND NC PT PS
L30 Trip 1 0 to 255 
RO Txt ND NC PT PS
L31 Trip 2 0 to 255 
RO Txt ND NC PT PS
L32 Trip 3 0 to 255 
RO Txt ND NC PT PS
L33 Trip 4 0 to 255 
RO Txt ND NC PT PS
L34 Trip 5 0 to 255 
RO Txt ND NC PT PS
L35 Trip 6 0 to 255 
RO Txt ND NC PT PS
L36 Trip 7 0 to 255 
RO Txt ND NC PT PS
L37 Trip 8 0 to 255 
RO Txt ND NC PT PS
L38 Trip 9 0 to 255 
RO Txt ND NC PT PS
L39 Reset Trip Log Off (0) or On (1)
RW Bit ND NC
L40 Drive Reset Off (0) or On (1) Off (0) RW Bit NC
L41 Trip 0 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS
L42 Trip 0 Time 00:00:00 to 23:59:59 
RO Time ND NC PT PS
L43 Trip 1 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS
L44 Trip 1 Time 00:00:00 to 23:59:59 
RO Time ND NC PT PS
L45 Trip 2 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS
L46 Trip 2 Time 00:00:00 to 23:59:59 
RO Time ND NC PT PS
L47 Trip 3 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS
L48 Trip 3 Time 00:00:00 to 23:59:59 
RO Time ND NC PT PS
L49 Trip 4 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS
L50 Trip 4 Time 00:00:00 to 23:59:59 
RO Time ND NC PT PS
L51 Trip 5 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS
L52 Trip 5 Time 00:00:00 to 23:59:59 
RO Time ND NC PT PS
L53 Trip 6 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS
L54 Trip 6 Time 00:00:00 to 23:59:59 
RO Time ND NC PT PS
L55 Trip 7 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS
L56 Trip 7 Time 00:00:00 to 23:59:59 
RO Time ND NC PT PS
L57 Trip 8 Date 00-00-00 to 31-12-99 
RO Date ND NC PT PS