Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
E300 Design Guide 389
Issue Number: 1
When set to On (1), indicates that an error has been detected during travel. The trip for the given error will only happen when the elevator has finished
the current travel.
The following trips are suppressed during a travel:
Motor thermistor Trip 24 (Thermistor)
Brake monitoring Trip 72 (Brk con 1 open), Trip 73 (Brk con 1 closd), Trip 74 (Brk con 2 open) and Trip 75 (Brk con 2 closd)
Motor contactor monitoring Trip 70 (Mot con open) and Trip 71 (Mot con closd)
Heat sink over temperature Trip 22 (OHt Power), the trip will happen when the next travel is initiated.
The direction signal monitoring Trip 76 (Dir change)
Control word watchdog bit monitoring, Trip 77 (Ctrl Watchdog).
The freeze protection monitoring, trip 60 (Freeze protect).
Drive OK (L05) indicates that the drive is not in the trip or the under voltage state if it is set to one.
Value Description
0 No travel interrupt
1 Travel interrupt during while waiting for the enable input in state 1, Elevator Software State (J03) = 1.
2 Travel interrupt during the motor contactor de-bounce time in state 2, Elevator Software State (J03) = 2.
3 Travel interrupt during ramping the drive torque / brake release logic in state3 Elevator Software State (J03) = 3.
4 Travel interrupt during the brake release delay in state 4, Elevator Software State (J03) = 4.
5 Travel interrupt during the load measurement delay in state 5, Elevator Software State (J03) = 5.
6 Travel interrupt during start optimization in state 6, Elevator Software State (J03) = 6.
7 Travel interrupt during acceleration in state 7, Elevator Software State (J03) = 7.
8 Travel interrupt during travelling in state 8, Elevator Software State (J03) = 8.
9 Travel interrupt during deceleration in state 9, Elevator Software State (J03) =
9.
10 T
ravel interrupt during creep state 10, Elevator Software State (J03) = 10.
11 Travel interrupt during positioning in state 11, Elevator Software State (J03) = 11.
12 Travel interrupt during brake apply delay in state 12, Elevator Software State (J03) = 12.
13 Travel interrupt during torque ramp / brake apply in state 13, Elevator Software State (J03) = 13.
L04 Global Warning
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
L05 Drive OK
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
Drive State LED
Normal power and Drive OK (L05) = 1 On continuously
Normal power and Drive OK (L05) = 0 Flashing: 0.5 s on and 0.5 s off
Standby power state Flashing: 0.5 s on and 7.5 s off