EasyManua.ls Logo

Emerson E300 Series - Page 415

Emerson E300 Series
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
E300 Design Guide 415
Issue Number: 1
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
O01
Load Measurement Direction
Output
Off (0) or On (1) RO Bit ND NC PT
O02
Load Measurement Direction
Invert
Off (0) or On (1) Off (0) RW Bit US
O03 Load Measurement Value
0 to 3276.7 % RO Num ND NC PT
O04 Load measurement time
±2000 ms
0 ms
RW Num US
O05 UPS Control Enable Off (0) or On (1) Off (0) RW Bit US
O06
UPS Maximum Power
Setpoint
0.00 to 655.35 kW 175.00 kW RW Num US
O07
UPS evacuation current full
load limit
0.0 to 6553.5 % 175.0 % RW Num RA US
O08
UPS evacuation current no
load limit
0.0 to 6553.5 % 175.0 % RW Num RA US
O09 Active Supply Off (0) or On (1)
RO Bit ND NC PT
O10 User Supply Select Off (0) or On (1) Off (0) RW Bit US
O11
Standard Under Voltage
Threshold
±VM_STD_UNDER_VOLTS V
200V drive: 175 V
400V drive: 330 V
575V drive: 435 V
690V drive: 435 V
RW Num RA US
O12 LV Supply Mode Enable Off (0) or On (1) Off (0) RW Bit US
O13
Low Under Voltage Threshold
Select
Off (0) or On (1) Off (0) RW Bit US
O14 Low Under Voltage Threshold ±VM_LOW_UNDER_VOLTS V
200V drive: 175 V
400V drive: 330 V
575V drive: 435 V
690V drive: 435 V
RW Num RA US
O15
Under Voltage Contactor
Close Output
Off (0) or On (1)
RO Bit ND NC PT
O16
Under Voltage System
Contactor Closed
Off (0) or On (1) Off (0) RW Bit
O17
Slow Rectifier Charge Rate
Enable
Off (0) or On (1) Off (0) RW Bit US
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save