418 E300 Design Guide
Issue Number: 1
This parameter defines the maximum UPS power in kW. This helps prevent the UPS from being overloaded during emergency evacuation when UPS
Control Enable (O05). = On (1).
This parameter defines the full load current percentage allowed during evacuation control to prevent the UPS from being overloaded. During
emergency evacuation the following functions are internally controlled to extend the operating time of the UPS:
Symmetrical Current Limit (B16)
Start Lock Enable (I22)
Maximum Speed Error Threshold (H15)
Maximum Distance Error Threshold (H16)
Start Optimizer Time (G48)
Load measurement time (O04)
UPS Maximum Power Setpoint (O06)
This parameter is used when UPS Control Enable (O05). = On (1).
This parameter defines the no load current percentage allowed during evacuation control to prevent the UPS from being overloaded. During
emergency evacuation the following functions are internally controlled to extend the operating time of the UPS:
Symmetrical Current Limit (B16)
Start Lock Enable (I22)
Maximum Speed Error Threshold (H15)
Maximum Distance Error Threshold (H16)
Start Optimizer Time (G48)
Load measurement time (O04)
UPS Maximum Power Setpoint (O06)
This parameter is used when UPS Control Enable (O05). = On (1).
O06 UPS Maximum Power Setpoint
Mode Open-Loop, RFC-A, RFC-S
Minimum 0.00 Maximum
655.35
Default 175.00 Units kW
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 2
Coding RW, BU
O07 UPS Evacuation Current Full Load Limit
Mode Open-Loop, RFC-A, RFC-S
Minimum 0.0 Maximum
6553.5
Default 175.0 Units %
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 1
Coding RW, RA, BU
O08 UPS Evacuation Current No Load Limit
Mode Open-Loop, RFC-A, RFC-S
Minimum 0.0 Maximum
6553.5
Default 175.0 Units %
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 1
Coding RW, RA, BU