CG Drives & Automation 01-7492-01r1 Functional description 107
Motor I
2
t Trip Type [2534]
Select the preferred way to react to a Motor I
2
t trip.
PT100 [2535]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
PT100 Trip Type [2536]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
PTC [2537]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
PTC Trip Type [2538]
Select the preferred way to react to a PTC trip.
Over Speed [2539]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
External Motor Temperature [253A]
Delay time starts counting when the fault disappears. When
the time delay has elapsed, the alarm will be reset if the
function is active.
External Motor Trip Type [253B]
Select the preferred way to react to an alarm trip.
Brake Fault [253C]
Delay time starts counting when the fault disappears. When
the time delay has elapsed, the alarm will be reset if the
function is active.
Encoder [253D]
Encoder delay time, starts counting when the fault
disappears. When the time delay has elapsed, the alarm will
be reset if the function is active.
2534 Motor I
2
tTT
Default: Trip
Trip 0 The motor will coast
Deceleration 1 The motor will decelerate
2535 PT100
Default: Trip
Trip 0 The motor will coast
Deceleration 1 The motor will decelerate
2536 PT100 TT
Default: Trip
Trip 0 The motor will coast
Decele-
ration
1 The motor will decelerate
2537 PTC
Default: Off
Range: Off, 1–3600 s (Off=0)
2538 PTC TT
Default: Trip
Trip 0 The motor will coast
Decele-
ration
1 The motor will decelerate
2539 Over speed
Default: Off
Range: Off, 1–3600 s (Off=0)
253A Ext MotTemp
Default: Off
Range: Off, 1–3600 s (Off=0)
253B Ext Mot TT
Default: Trip
Trip 0 The motor will coast
Deceleration 1 The motor will decelerate
253C Brk Fault
Default Off
Range: Off, 1–3600 s (Off=0)
253D Encoder
Default: Off
Range: Off, 1–3600 s (Off=0)